T1 - Estimation of Heart Rate Directly from ECG Spectrogram in Neonate Intensive Care Units
AU - Cabrera-Quiros, Laura
AU - Varisco, Gabriele
AU - Zhan, Zhuozhao
AU - Long, Xi
AU - Andriessen, Peter
AU - Cottaar, Eduardus J.E.
AU - Van Pul, Carola
N1 - Publisher Copyright:
© 2020 IEEE.
PY - 2020/7
Y1 - 2020/7
N2 - This paper presents a simple yet novel method to estimate the heart frequency (HF) of neonates directly from the ECG signal, instead of using the RR-interval signals as generally done in clinical practices. From this, the heart rate (HR) can be derived. Thus, we avoid the use of peak detectors and the inherent errors that come with them.Our method leverages the highest Power Spectral Densities (PSD) of the ECG, for the bins around the frequencies related to heart rates for neonates, as they change in time (spectrograms).We tested our approach with the monitoring data of 6 days for 52 patients in a Neonate Intensive Care Unit (NICU) and compared against the HR from a commercial monitor, which produced a sample every second. The comparison showed that 92.4% of the samples have a difference lower than 5bpm. Moreover, we obtained a median MAE (Mean Absolute Error) between subjects equal to 2.28 bpm and a median RMSE (Root Mean Square Error) equal to 5.82 bpm. Although tested for neonates, we hypothesize that this method can also be customized for other populations.Finally, we analyze the failure cases of our method and found a direct co-allocation of errors due to moments with higher PSD in the lower frequencies with the presence of critical alarms related to other physiological systems (e.g. desaturation).
AB - This paper presents a simple yet novel method to estimate the heart frequency (HF) of neonates directly from the ECG signal, instead of using the RR-interval signals as generally done in clinical practices. From this, the heart rate (HR) can be derived. Thus, we avoid the use of peak detectors and the inherent errors that come with them.Our method leverages the highest Power Spectral Densities (PSD) of the ECG, for the bins around the frequencies related to heart rates for neonates, as they change in time (spectrograms).We tested our approach with the monitoring data of 6 days for 52 patients in a Neonate Intensive Care Unit (NICU) and compared against the HR from a commercial monitor, which produced a sample every second. The comparison showed that 92.4% of the samples have a difference lower than 5bpm. Moreover, we obtained a median MAE (Mean Absolute Error) between subjects equal to 2.28 bpm and a median RMSE (Root Mean Square Error) equal to 5.82 bpm. Although tested for neonates, we hypothesize that this method can also be customized for other populations.Finally, we analyze the failure cases of our method and found a direct co-allocation of errors due to moments with higher PSD in the lower frequencies with the presence of critical alarms related to other physiological systems (e.g. desaturation).
UR - http://www.scopus.com/inward/record.url?scp=85090994740&partnerID=8YFLogxK
U2 - 10.1109/EMBC44109.2020.9176176
DO - 10.1109/EMBC44109.2020.9176176
M3 - Contribución a la conferencia
AN - SCOPUS:85090994740
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 320
EP - 323
BT - 42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society, EMBC 2020
Y2 - 20 July 2020 through 24 July 2020
ER -