Resumen
This paper presents a two-control loop design considering the nonlinear time-varying characteristics of a single-phase grid-connected photovoltaic (PV) full-bridge central inverter. The control scheme design is based on the energy-balance modeling of the PV system and enables the design of a voltage loop linear discrete controller ensuring the stability of the system for the whole range of PV array operating conditions. A set of experimental results carried out on a laboratory prototype is provided to validate the proposed approach.
Idioma original | Inglés |
---|---|
Páginas (desde-hasta) | 2734-2743 |
Número de páginas | 10 |
Publicación | IEEE Transactions on Industrial Electronics |
Volumen | 55 |
N.º | 7 |
DOI | |
Estado | Publicada - jul 2008 |
Publicado de forma externa | Sí |