T1 - Calibration of Low-Cost Moisture Sensors in a Biochar-Amended Sandy Loam Soil with Different Salinity Levels
AU - Gómez-Astorga, María José
AU - Villagra-Mendoza, Karolina
AU - Masís-Meléndez, Federico
AU - Ruíz-Barquero, Aníbal
AU - Rimolo-Donadio, Renato
N1 - Publisher Copyright:
© 2024 by the authors.
PY - 2024/9
Y1 - 2024/9
N2 - With the increasing focus on irrigation management, it is crucial to consider cost-effective alternatives for soil water monitoring, such as multi-point monitoring with low-cost soil moisture sensors. This study assesses the accuracy and functionality of low-cost sensors in a sandy loam (SL) soil amended with biochar at rates of 15.6 and 31.2 tons/ha by calibrating the sensors in the presence of two nitrogen (N) and potassium (K) commercial fertilizers at three salinity levels (non/slightly/moderately) and six soil water contents. Sensors were calibrated across nine SL-soil combinations with biochar and N and K fertilizers, counting for 21 treatments. The best fit for soil water content calibration was obtained using polynomial equations, demonstrating reliability with (Formula presented.) values greater than 0.98 for each case. After a second calibration, low-cost soil moisture sensors provide acceptable results concerning previous calibration, especially for non- and slightly saline treatments and at soil moisture levels lower than 0.17 cm3cm−3. The results showed that at low frequencies, biochar and salinity increase the capacitance detected by the sensors, with calibration curves deviating up to 30% from the control sandy loam soil. Due to changes in the physical and chemical properties of soil resulting from biochar amendments and the conductive properties influenced by fertilization practices, it is required to conduct specific and continuous calibrations of soil water content sensor, leading to better agricultural management decisions.
AB - With the increasing focus on irrigation management, it is crucial to consider cost-effective alternatives for soil water monitoring, such as multi-point monitoring with low-cost soil moisture sensors. This study assesses the accuracy and functionality of low-cost sensors in a sandy loam (SL) soil amended with biochar at rates of 15.6 and 31.2 tons/ha by calibrating the sensors in the presence of two nitrogen (N) and potassium (K) commercial fertilizers at three salinity levels (non/slightly/moderately) and six soil water contents. Sensors were calibrated across nine SL-soil combinations with biochar and N and K fertilizers, counting for 21 treatments. The best fit for soil water content calibration was obtained using polynomial equations, demonstrating reliability with (Formula presented.) values greater than 0.98 for each case. After a second calibration, low-cost soil moisture sensors provide acceptable results concerning previous calibration, especially for non- and slightly saline treatments and at soil moisture levels lower than 0.17 cm3cm−3. The results showed that at low frequencies, biochar and salinity increase the capacitance detected by the sensors, with calibration curves deviating up to 30% from the control sandy loam soil. Due to changes in the physical and chemical properties of soil resulting from biochar amendments and the conductive properties influenced by fertilization practices, it is required to conduct specific and continuous calibrations of soil water content sensor, leading to better agricultural management decisions.
KW - calibration
KW - capacitive sensor
KW - salinity
KW - soil moisture content
KW - soil moisture sensor
UR - http://www.scopus.com/inward/record.url?scp=85205234387&partnerID=8YFLogxK
U2 - 10.3390/s24185958
DO - 10.3390/s24185958
M3 - Artículo
C2 - 39338703
AN - SCOPUS:85205234387
SN - 1424-8220
VL - 24
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 18
M1 - 5958
ER -